O:2/0 closes (Motor starts turning forward) 9. O:2/1 opens (Motor stops turning in reverse) 8b. O:2/1 closes (Motor is turning in reverse direction) 7. I:1/0 is closed I:1/1 is open Start O:2/0 closes (Motor is turning in forward direction) Open I:1/0 to indicate that the box is departing the West end (The NO switch opens) Close I:1/1 to indicate box arriving East end 6a. Rung 4 is the implementation of the reverse equation. Completely design and de-bug a ladder control circuit which will automatically position and fill the boxes which are continuously sequenced along the conveyor.
Silo logix pro simulator#
Rung 1 is A, Rung 3 is B, rung 2 is (Anot)(Bnot), and O:24 in rung 1 is not(Anot Bnot). Silo Simulator Exercise and Solution (This exercise is based on LogixPro PLC simulator) Exercise 1 Continuous Operation. If we call rung 1 = A and the third element = B then A + B = not(Anot Bnot). Their output, O:2/4 is applied to rung zero. Rungs 2 and 3, combined are the DeMorganized representation of the third member of the forward equation, ored to rung 1. Rung 1 is the implementation of the first two members of the forward equation. (The negated function provides the needed continuity in the rung). We want reverse operation only when the switch is in its true, open state.), or when (O:2/1)(I:1/0not) The motor is running in reverse and the West limit switch is open. O:2/1 is true (motor runs reverse) when I:1/1 + The West limit switch is open (Remember it is NO. The East limit switch had to be included in all the elements to prevent reverse action when moving forward. The negated function shows continuity when the switch is open), or when (O:2/0)(I:1/1not) + The motor is running forward and the East limit switch is not closed (hold function), or when (O:2/1not)(I:1/0) The motor is not running in reverse and the West limit switch is closed (reset function). Logic equation: O:2/0 = (I:1/4)(I:1/1not) + (O:2/0)(I:1/1not) + (O:2/1not)(I:1/0) O:2/1 = I:1/1 + (O:2/1)(I:1/0not) In words: O:2/0 is true (motor runs forward) when (I:1/4)(I:1/1not) + The start switch is open and the East limit switch is not closed (remember that the East limit switch is NO. Outputs: O:2/0, Forward direction output O:2/1, Reverse direction output Auxiliary logic inputs and outputs used to counteract the simulator limitations: O:2/2 O:2/3 O:2/4 West-end limit switch East-end limit switch Start switch Stop switch
![silo logix pro silo logix pro](https://i.ytimg.com/vi/LMTHxesMJF4/mqdefault.jpg)
Implement the solution using the LogixPro simulator. The stop switch is momentary, normally closed. Assume that the limiting positions are signaled by two normally open limit switches and the start switch is of the momentary, normally open type. Then it reverses direction to bring the box back to its starting position and the cycle continues until the Stop switch is pressed. When the switch is pressed, the motor rotates causing the conveyor to move one way. Assume that the conveyor is activated by a motor. Once the start switch is pressed, the box moves back and forth between two limiting positions. In other words, the box is at the West end. All future updates may be downloaded and installed at will, and without concern for the continued and unrestricted operation of LogixPro.Forward-Reverse Motor Simulation in TLP LogixPro Problem: A box is at the West end of the conveyor A start switch is pressed The box moves to the East end. In addition, there will be no need to purchase new CDs when LogixPro is updated or features are added. Thereafter, the CD acts as the "Key", and LogixPro will start-up fully unlocked and remain so while the CD is present. When inserted into the drive of a computer that does not yet have LogixPro installed, it will prompt the user to do so.
Silo logix pro full#
The CD contains the full LogixPro installation program. Just insert the CD, and any computer having LogixPro installed will detect the SafeDisc Key, and allow the fully unrestricted use of LogixPro.
![silo logix pro silo logix pro](https://www.researchgate.net/profile/Sunita-Kumari-14/publication/330901432/figure/fig2/AS:987372258873346@1612419299312/More-Realistic-and-Challenging-Programming_Q320.jpg)
Whether at home, office, or school, LogixPro can now be ready for use. The CD/Key Edition brings complete portability to LogixPro, and is ideal for those wishing to utilize LogixPro on multiple computers. I have attached a link for my solution to the third silo exercise. I am a student at Lafayette Technical College (Louisiana) when I am not working (7/7 offshore) One of my current classes is using the LogixPro Training program as an intro to PLCs.
Silo logix pro full version#
LogixPro PLC Simulator is now available on copy-protected CD. View Full Version : LogixPro Silo Simulator. compressors, silos, traffic lights, car washes, elevators.
Silo logix pro software#
One of the main advantages of using PLCLogix is that it provides much-needed hands on experience in the operation of RSLogix and ControlLogix software and hardware.
![silo logix pro silo logix pro](https://canadu.com/lp/doc/nctr/cn1-480x388.gif)
We are a distributor for LogixProâ„¢, an RSLogix 500 Simulator! This "virtual PLC" environment or PLC Simulator allows the learner to apply the knowledge gained in The PLCTrainer without the expense of purchasing RSLogix or even a PLC. PLCLogix is designed to simulate the functionality of the Logix 5000 Programmable Logic Controller (PLC).